The conditions referenced in this section
relate specifically to hazardous area
applications and must be followed.
In accordance with clause 5.1 of EN 60079-1,
the critical dimensions of the flamepaths are:
• Contact the manufacturer for information on
the dimensions of the flameproof joints.
• The apparatus must only be used in areas
where there is low risk of impact.
• Do not charge battery pack in the hazardous
area.
• The battery must be removed from the
camera and charged in the CorDEX
Instruments ToughPIX II charging bay. Using
a different charging device can cause
damage and void certification.
• The ToughPIX II 2410 Series digital camera
incorporates a protected battery system
with a non-replaceable fuse. This fuse is
only to be replaced by CorDEX Instruments
or a CorDEX Instruments Approved Repair
Facility. Failure to do so will void the
certification.
• Ensure that the ToughPIX II 2410 Series
digital camera battery pack is secured
using the plug provided. If the plug is lost,
only replace with a plug of the correct size
and type. If in doubt, contact your nearest
CorDEX Instruments representative.
• The ToughPIX II 2410 Series digital camera
is manufactured from aluminium alloy; and
must contain less than 7% magnesium by
weight and incorporates toughened glass
windows. This should be taken into account
when considering the end use application.
• The ToughPIX II 2410 Series digital camera
cannot be maintained in the field and must
be returned to the manufacturer should
repair or maintenance be required.
• USB communications with the ToughPIX II
2410 Series digital camera must only occur
within the non-hazardous area.
• When replacing the battery pack, the screw
must be re-tightened to a torque of 1.5-4Nm
and the cover cap replaced.
• Only CorDEX battery pack CDX2400-011 shall
be used.
• Do not enable wifi in the hazardous area.