Automatic Transfer Switch 200A Circuit Breaker Switch for Generators

Product Details

Automatic Transfer Switch 200A Circuit Breaker Switch for Generators
Automatic Transfer Switch 200A Circuit Breaker Switch for Generators
Automatic Transfer Switch 200A Circuit Breaker Switch for Generators
Automatic Transfer Switch 200A Circuit Breaker Switch for Generators
Automatic Transfer Switch 200A Circuit Breaker Switch for Generators
Automatic Transfer Switch 200A Circuit Breaker Switch for Generators

Radin Electric provides ATS design engineering and full after sales support for a wide range of automatic transfer switch applications. We offer onsite electrical audits to assist in determining the correct product and installation to meet your exact needs and requirements.

Technical Specification

Model RDQ3CM
Working Voltage AC400V 50/60Hz
Operation Mode Auto and Manual
Transfer Mode Auto Transfer with Auto Recovery
Auto Transfer without Auto Recovery
Grid Generator
Rated Current 100A to 1250A
Poles 3P and 4P
Color White / Black
Controller A / B Type as per customer

About ATS

RDQ3CM series intelligent dual power auto transfer switch (brief as ATS) suitable for emergency power supply system with rated AC voltage 400V 50/60Hz. When one power source fault can auto interchange from main power to backup power no need manual operation to protect the power supply stability. Mainly apply to the important place which not allow power cutoff such as Hospital shopping mall bank chemical industry metallurgy high building military facilities and fire fighting etc.

Product Structure

RDQ3CM series intelligent ATS comprised with two 3P or 4P MCCB and its accessories (Aux. Contact Alarm contact) Mechanical interlocking transmission mechanism intelligent controller etc. Have two constructions of integral and split type. Integral type is controller and executive unit installed at a same base Split type is controller installed on the panel and the executive unit installed on the base inside the panel box a 2m length signal cable connecting the controller with the executive unit.

RDQ3CM Series Advantages

1. There is a reliable mechanical interlock device and electric interlock protection between two MCCB completely avoid the possibility of two MCCB closed at same time
2. Intelligentized controller adopt the single chip microcomputer (SCM) as the control core simple hardware strong functions easy extension high reliability
3. Intelligent controller circuit layout design adopt power sampling separate with SCM control from the hardware to overcome the electromagnetic interference
4. With short circuit over load protection functions over volt under volt phase missing auto transfer function and intelligent alarm function
5. Auto transfer data by external setting freely with operation motor protect function
6. Signal connecting cable have passed FLUKE instrument channel test anti near crosstalk attenuation crosstalk and back wave loss can meet the test criteria for permanent link
7. The ATS controller installation method provide customer with highly autonomy ( split installation only need simply connect the attached RJ45 signal cable to the corresponding terminal port)
8. Customer can according to the operating requirements to select correct controller A Basic type B Intelligent digital display type

Working Mode

RDQ3CM series intelligent dual power ATS have two working mode Auto mode and Manual mode
l Auto Mode RDQ3CM series ATS according to the controller functions have three modes Auto change Auto recovery (R) Auto change no recovery (S) and Power Grid Generator (F) the first two mode used in power grid power grid system the latter mode is used in power grid generator system.
l Manual mode manual mode has three working mode main power backup power and breaker trip modes. Under manual working mode there will be no auto transfer function.
1). Main power mode Forced disconnecting backup power and turn ON the main power
2). Backup power mode Forced disconnecting the main power and turn ON the backup power
3). Breaker trip mode To disconnecting two power source also can switch on the fault tripped circuit breaker.

Working Conditions
Ambient Temperature
Max. 60 C
Min. 20 C
24h average not more than 35 C
Altitude Not more than 2000m
Atmospheric conditions humidity not more than 50 at max. 40 C higher humidity is allowed at lower temperature at most wet month the average max humidity is 90 at the average min temperature 25 C and have considered the condensation on the product surface due to temperature variation.

Dlivery Terms
Shipment Express Air express

We've got CE TUV KEMA CCC certificate for ATS which also meets the ISO9001 standard and the factory has go through SGS test.

FAQ
1. What's the warranty term
24 Monthes.
2. How long does it take to deliver my goods
Normally samples can be delivered in 2 days. Customer designed sampleswill be delivered in 3 7 days.
3. Do you offer sample
Yes we offer sample order for customer to test the goods.
4. What kinds of payment terms do you accept
We offer kinds of payment ways foe customer to chose from. T/T L/C Aliexpress Western union etc.
5. What if there's quality peoblem
We offer replacement for the goods as soon as there is a quality problem with the goods and the fright is on our account to cut down the customer's loss to the lowest.

We are sure any of your questions will get our prompt reply just leave the message

Contact Information

Contact PersonLena Yang
Telephone+86(577) 57156212
Fax Number+86(577) 57156212
Websitehttps://www.gmdu.net/corp-915111.html
Post Code325600
AddressNo.319 Latitude 18th Road, Economic Development Zone, Yueqing City, Zhejiang, China.
About Us - Contact Us - Privacy Policy - Daily Updates - Report Abuse