Welcome, Guest Sign InSign Up
Product Details
JYM Syringe Pump with Drug Library JZB-1800Y
JYM Syringe Pump with Drug Library JZB-1800Y
JYM Syringe Pump with Drug Library JZB-1800Y
JYM Syringe Pump with Drug Library JZB-1800Y
Features
• Compatible with syringes of most of the standard brands.
• Automatic Calibration for syringes.
• Five working modes: Rate control mode, Time control mode, Weight control mode, Drug Dose control mode and Bolus control mode.
• Built in rechargeable battery (Lithium-ion polymer battery).
• 8 hours internal battery backup.
• Spec of the fuse: F1AL /250V, two (inside).
• Alarm functions: occlusion, empty, near empty, low battery, infusion over, syringe loose, etc
• Three levels of the occlusion limited pressure: high, middle and low.
• Three levels of alarm sound: high, middle and low.
• The syringe pump goes into KVO mode automatically when infusion is completed.
• Purge / Bolus function.
• Waterproof class: IPX4


Technical Specification
1. Flow range (Rate mode):
50 ml syringe: 0.1 – 1800.0 ml / hr (0.1 ml / hr step)
30 ml syringe: 0.1 – 1200.0 ml / hr (0.1 ml / hr step)
20ml syringe: 0.1 – 800.0 ml / hr (0.1 ml / hr step)
10ml syringe: 0.1 – 400.0 ml / hr (0.1 ml / hr step)
5 ml syringe: 0.1 – 200.0 ml / hr (0.1 ml / hr step)
2. Accuracy: +/- 2% (After correct calibration)
3. Time setting mode range:
Volume: 0.1 – 999.9ml, 0.1ml step.
Time: 0.1 – 999.9min, 0.1min step.
4. Weight setting mode range:
Sol. volume: 0.1 – 199.9ml, 0.1ml step.
Drug mass: 0.1 – 999.9ml, 0.1 ml step.
Dose: 0.001 – 9.999, 0.001 step;
10.00 – 99.99, 0.01 step;
100.0 – 999.9, 0.1step;
1000 – 9999, 1 step.
Dose Unit: ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h, IU/h, U/kg/h, ng/kg/min.
Weight: 0.1- 300.0kg, 0.1kg step.
5. Bolus setting mode range:
Bolus Volume: 0.1ml – 100.0ml, 0.1ml step
Bolus Rate: 5ml: 0.1ml/h – 200.0ml/h, 0.1ml/h step
10ml: 0.1ml/h – 400.0ml/h, 0.1ml/h step
20ml: 0.1ml/h – 800.0ml/h, 0.1ml/h step
30ml: 0.1ml/h – 1200.0ml/h, 0.1ml/h step
50ml (60ml): 0.1ml/h – 1800.0ml/h, 0.1ml/h step
6. Purge rate: 1800.0ml/h (50ml), 1200.0ml/h (30ml), 800.0ml/h (20ml), 400.0ml/h (10ml), 200.0ml/h (5ml)
7. Volume limits range: 0 – 9999.9ml, 0.1ml step.
8. Power supply: AC 100 – 240V, 50/60Hz.
9. Power consumption: ≤25VA
10. Class: I
11. Type: CF
12. Size: 230mm (W) x 150mm (H) x 125mm (D)
13. Net Weight: 2.2Kg. (Approx)
14. Operating condition: Ambient temperature 10-40degree C
Relative humidity 20-90%
15. Storage condition: Ambient temperature: -10~55degree C
Relative humidity: 10~90%.
16. Possibility of creation of a database about used solutions (drug)